How to troubleshoot your windlass: if it does not operate
68,097
Published 2019-10-23
The anchor windlass does not work when a control is operated
Possible causes:
1.1 Protection switch in OFF position
1.2 Lack of voltage in the system
1.3 Failure of the control box
1.4 Failure of the control
1.5 Failure of the electric motor
Solution:
1.1 Check the protection switch and set it in the ON position
1.2 Check the charge status of the battery, check connections
1.3 Check and possibly replace the control box
1.4 Check and possibly replace the control
1.5 Measure the electric motor voltage; if it is OK, check the brushes and clean them. If it does
not work, replace the electric motor
www.lofrans.com/
All Comments (8)
-
Good videos! You should make one about maintenance, specially preventive.
-
Poli hrisimo video. Efharistoume
-
Our windlass switch is working but the anchor chain doesnt work..how is it?
-
Great explanation! But how to winch up the anchor manually? is it possible with the x2 or the x1?
-
A good first step is to hit the motor with a hammer while pushing the controls down or up Not a joke, the internals can become sized after a long time not being used and the hammer can rattle things loose again.
-
Where do I find the breaker?
-
Our main windlass switch is working.but the anchor chain doesnt work..what is the problem?