XSY-AT1 VFD Podłączenie Falownika Silnik 3 Fazowy 2.2KW 220V AC 12A

18,400
0
Published 2023-05-02
Connecting the XSY-AT1 2.2 kW inverter to a 3-phase motor.
Single phase frequency inverter 2.2KW 220V AC 12A
I will not show all programs . The instruction is very simple and clear.

All Comments (17)
  • Question - is it possible to set up the VFD Controller XSY-AT1 so that when turned on it works at high speed, about 2-3 minutes, but after 2-3 minutes of operation to a pre-set low speed? A pool water pump is connected to the XSY-AT1 frequency converter.
  • @Dipple
    I’m having an Err 1 code when I start the VFD. My motor is set to the high voltage does it need to be changed to low voltage?
  • @MavG
    The XSY-AT1 you are working is a model from 2023?. I found one on amazon but its a white, maybe is from an older version. Asking so i can know wich one i should get. Thank you. Btw, what is the exact name and model the tools you are using on the 1:15 minute and also the 1:49. I wanna get those from amazon right away.
  • Pytanie czy istnieje możliwość zaprogramowanie tego przetwornika częstotliwości tak aby silnik krecił się ok 30 obr na min? Jeśli tak to jak to zrobić?
  • @PatHudgins
    ? My wiring is correct. Two 110v hot wires input. No neutral. The inverter spins up to 60hz. The motor does nothing. The table saw has separate Allen Bradley start and stop switches. They are not wired into the remote start/run terminals in the inverter. I thought using the Run button on the inverter would supply current to the motor. I'm getting 130v on all 3 terminals in the Allen Bradley junction box on the saw. Any advice?
  • 👍👍ten falownik ma funkcję hamowania silnikiem? tak to przynajmniej wyglądało jak zmieniałeś obroty
  • @ksadmm5453
    Four panels go 560 watts and the second thing is which GFT will be applied to the three piece motor
  • @user-xx2wk6jp5d
    Hi can you please help i have a cross cut saw and need to put in a two way switch so that i can have it running continuously or on the hand button stop&start also i need to put in an emergency stop
  • @MadeInDamian
    Witam. Można konkretny namiar na produkt . Szukam na ale... Ale dużo podobnych jest . Dziękuję i pozdrawiam 👊
  • @Roberto-cc4el
    Ciao...siccome ho anch'io un ATI 1 2.2KW installato su un motore trifase 750w per il mio tornio ... ed ho un problema che quando gira il motore mi genera una anomalia tra massa e neutro di circa 20/24v non è normale e mi fa interferenza nel display lcd 16x2 del contagiri comandato da arduino...ho visto nel tuo video che hai messo al motore un cavo a 4 poli SCHERMATO come mai? Grazie in anticipo.
  • Does the shielded cable do anything? the frequency converter also needs to be shielded, right?